Free Chlorine Analyser Requires No Reagents to Provide Accurate Monitoring at Economical Cost

Municipal water engineers and technicians who want a more economical and simpler way to ensure the disinfection of water with chlorine systems will find the FC80 Free Chlorine Analyser from Electro-Chemical Devices eliminates the need for expensive reagents while providing highly accurate measurement performance.

The plug-n-play FC80 Free Chlorine Analyser installs quickly right out of the box. The FC80’s advanced panel mount design includes built-in flow control, which eliminates the need for complicated pressure regulators and rotometers. Built-in automatic pH compensation with ECD’s highly intelligent S80 pH Sensor also eliminates the need for expensive reagents to reduce maintenance and life-cycle costs.

The dependable FC80 Analyser monitors free chlorine in drinking water from 0.05 – 20 ppm chlorine as the standard range or 0.01 - 5.00 ppm with the low range sensor. The FC80 is compliant with EPA method 334.0 for measuring drinking water. It also supports industrial applications including rinse water, cooling water or other fresh water sampling.

The FC80’s panel mount design incorporates a constant head flow control device, a pH sensor, a chlorine sensor and ECD’s T80 analyser/transmitter conveniently mounted on a PVC panel. Connect the sample and drain lines, connect the power and outputs and it is ready to use. Calibration is accomplished by DPD comparison.

ECD’s T80 Analyser is designed with an amperometric sensor. This sensor measures only the only the hypochlorous acid component of the free chlorine and the analyser calculates the balance using either the measured pH or a user defined fixed value. The use of the pH sensor provides accurate compensation for samples between pH 6 and pH 9, thus eliminating the need for expensive sample conditioning systems to control the pH of the solution.

The free chlorine necessary for disinfection exists in solution as a pH dependent ratio of hypochlorous acid (~100% at pH 5) and hypochlorite ion (~100% at pH 10). Chlorine has been a popular disinfectant for water treatment to ensure public health. Disease causing organisms such as Cholera, Hepatitis A, Typhoid Fever and Dysentery are eliminated with Chlorine, along with slime bacteria, algae and molds that can grow in water storage facilities such as reservoirs and storage tanks.

There have been several other methods developed to measure chlorine in drinking water applications. Colorimetric systems, for example, have been popular, but require the use of reagents that must be replaced monthly in order to ensure accurate measurement. With its amperometric sensor design, the FC80 eliminates the need for expensive reagents and offers an economical operating cost for municipal water districts that must manage tight budgets.

The FC80 Analyser is available with either 110-240 VAC or 24 VDC power. Parameters can be graphically displayed with user defined line, bar or gauge style graphs. The standard configuration has two 4-20 mA outputs, three alarm relays and a MODBUS RTU.

The user friendly FC80 is available with an Auto Clean option that includes a solenoid actuated spray cleaner using either 30 psi process water or air. An easily adjusted timer controls the period and duration of the cleaning cycle.


Digital Edition

AET 28.4 Oct/Nov 2024

November 2024

Gas Detection - Go from lagging to leading: why investment in gas detection makes sense Air Monitoring - Swirl and vortex meters will aid green hydrogen production - Beyond the Stack: Emi...

View all digital editions

Events

POLLUTEC

Nov 26 2024 Paris, France

Turkchem

Nov 27 2024 Istanbul, Turkey

Biogas Convention & Trade Fair 2024

Nov 27 2024 Hanover, Germany

Safety & Health Expo 2024

Dec 02 2024 London, UK

View all events