Environmental Laboratory
Small and Reliable Intrinsically Safe Dew Point Transmitter for Cng Applications
Nov 18 2008
This intrinsically safe transmitter has powerful processing capability allowing for the first time, the on-board calculation of ppm(v) moisture content in selectable ranges from 0 to 3000ppm. Application software allows the user to configure output parameters, ranges and scaling.
The key to the transmitterâs performance is its sensor technology. Michell Instrumentsâ Advanced Ceramic Moisture Sensor is coupled with advanced microprocessor-based measurement circuitry to produce a fully calibrated and interchangeable sensor transmitter. All calibration data is stored within the transmitterâs memory and so calibration exchange, or service, can be effected in seconds, even by untrained personnel. The Easidew TX I.S. is simply disconnected, removed from its sampling block and replaced by a new fully calibrated unit.
The Easidew TX I.S. the perfect choice for measurement of dew point or moisture content. Specific applications include CNG (compressed natural gas) dryers, hydrogen coolant in power stations, industrial/hazardous gas manufacture and supply and many more.