CEMS
MGA Prime Q MCERTS to T-CEMS, EN 15627-4:2017 certified
Aug 10 2021
The MGAprime Q is a portable Stack Gas Analyser suitable for use with standard reference methods and for verifying and calibrating installed CEMS, according to the requirements of the EN 14181. The MGAprime Q covers O2, CO, NOx, SO2 as part of its certification plus additional measurements for CH4, C3H8, CxHy and N2O. N2O will be added soon to the MCERTS scope of certification.
The Unit is MCERTS certified to EN 15627-4 : 2017 which finally defines the specifications for Portable Emissions Analysers used for official monitoring and calibration/verification of CEMS
Due to its portability and battery back up which allows to move the analysers between sampling points with-out turn it off, the MGA Prime Q is particularly suitable in applications where multiple samples points are required. Testing Generators has never been so fast.
This measuring system is the world’s most compact solution that consists of a complete gas conditioning system with a heated gas sampling probe and line, and the analyser with integrated gas cooler and gas analysis modules.
The analyser can simultaneously measure nine gas components (O2, CO, CO2, NO, NO2, N2O, SO2, CH4, C3H8) as well as gas temperature, flow velocity with calculation of flow rate.
The gas components are measured with a paramagnetic sensor and innovative, infrared (NDIR) measurement technology. Measurements of SO2 and NOx meet the requirements of equivalence with the standard reference methods. This eliminates the need to use complex and costly technology such as a chemiluminescence detector with an upstream NO2 to NO converter. Equivalence to SRM for NOx ( EN 14792) have been demonstrated by applying the EN 14793
The analytical technology is based on a drift-free and precise infrared measurement technique, where the cross-interferences of H2O and the measured gas components are compensated by software.
The large touch and swipe colour display enables easy, intuitive operation with a variety of graphic options. The measurement data can be transferred via LAN, WLAN, 4-20mA, RS485 and USB stick.
For further information please click here or email our team.
Digital Edition
AET 28.4 Oct/Nov 2024
November 2024
Gas Detection - Go from lagging to leading: why investment in gas detection makes sense Air Monitoring - Swirl and vortex meters will aid green hydrogen production - Beyond the Stack: Emi...
View all digital editions
Events
Jan 12 2025 Abu Dhabi, UAE
Jan 14 2025 Abu Dhabi, UAE
Jan 20 2025 San Diego, CA, USA
Carrefour des Gestions Locales de L'eau
Jan 22 2025 Rennes, France
Safety, Health & Wellbeing LIVE
Jan 22 2025 Manchester, UK