Rapid measurement of FOG (Fat, Oil and Grease) from waste-water using bench-top NMR


Date: 09:00:00 - Nov 22 2018
Speakers: Dr Kevin Nott

Measurement of Fats, Oils and Grease (FOG) in waste water is a crucial parameter in water quality control and environmental monitoring performed by water suppliers laboratories and environmental authorities. Traditionally this is carried out by passing a volume of water through a filter which collects both FOG and solid particulates; after drying the filter, the FOG is determined by Soxhlet analysis. However the Soxhlet method is a long and laborious process, requires skilled operators and the use of hazardous solvents which need to be disposed of. Furthermore, the method is not very accurate or sensitive, and the solvents that are used today are unlikely to extract all the FOG; the original chlorinated solvents used are now banned by the Montreal protocol. In contrast, bench-top, or time domain, NMR is rapid, accurate and solvent-free.

The MQC+ bench-top NMR analyser was calibrated using a set of standards prepared gravimetrically by applying known amounts of vegetable/mineral oil mixtures to filter papers. Subsequently various dried filter samples were measured by NMR and then by Soxhlet for comparison; this is possible because the NMR technique is non-destructive. In general, the results showed that NMR gives higher results and therefore is likely to be more accurate than Soxhlet analysis which is unable to measure all the FOG. In addition the NMR measurement repeatability is good.

In conclusion, the sensitivity of the NMR method enables accurate measurements of grease /oil content on a single filter sheet. In common with the Soxhlet method, the samples have to be dried overnight. No additional preparation is required apart from sample conditioning at 40°C to mobilise the FOG for NMR analysis, and a single sample measurement is rapid (typically 5 minutes). After conditioning, the samples can be measured in batches which is amenable to automation.

Free to watch

Sessions are free to watch. Please login to view this session or create an account.



Speakers


 Dr Kevin Nott
Dr Kevin Nott (Oxford Instruments)

Dr Kevin Nott is the product manager and applications specialist for the MQC+ analyser. He completed his first and Master degrees in chemistry at the University of East Anglia (1991-1995) which included a research project at the Institute of Food Research. He then studied for his Doctorate at the University of Cambridge (1995-1999) for which he investigated NMR relaxometry and imaging (MRI) applications in the food industry. After working as a post-doctoral researcher, he joined Oxford Instruments in May 2005. Since then he has been primarily working on bench-top (also known as time domain) NMR applications for quality control and research in the food, agriculture, polymer, petrochemical, pharmaceutical, water and other industries.


Digital Edition

AET 28.2 April/May 2024

May 2024

Business News - Teledyne Marine expands with the acquisition of Valeport - Signal partners with gas analysis experts in Korea Air Monitoring - Continuous Fine Particulate Emission Monitor...

View all digital editions

Events

The World Biogas Expo 2024

Jul 10 2024 Birmingham, UK

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

Australasian Waste & Recycling Expo

Jul 24 2024 Sydney, Australia

Chemical Indonesia

Jul 30 2024 Jakarta, Indonesia

China Energy Summit & Exhibition

Jul 31 2024 Beijing, China

View all events