Accurate Benzene, Toluene, Ethyl-Benzene and Xylene (BTEX) Measurements at Low ppb Levels in Real Time

Author: Dr Julian Iredale, CTO, Duvas Technologies Ltd. Email:  j.iredale@duvastechnologies.com, Web: www.duvastechnologies.com on behalf of Duvas Technologies Ltd

Free to read

This article has been unlocked and is ready to read.

Download

There has always been a difficulty in accurately quantifying benzene in air. Until recently, the only viable method of specifically measuring benzene at environmental levels (10 – 50 ppb) was through the use of grab samples and GC/MS. The DV3000 UV Gas Analyser from Duvas Technologies has the ability to accurately analyse a wide range of gases, including BTEX gases, simultaneously to ppl levels without cross-interference between species.

The DV3000 uses closed path spectroscopy and a DOAS-based technique to feed emission data to an advanced algorithm. Each species corresponds to a unique absorption spectrum; the algorithm is able to match the species via this ‘fingerprint’ allowing for detection and differentiation between species in complex mixtures. The DV3000 design performs analyses in a stationary and mobile mode. Using high performance Lithium battery packs, field surveys can be performed for up to six hours. These packs can easily be hot-swapped during analysis for uninterrupted operation and prolonged field deployment. The HEPA filter and mesh system prevents mirror contamination from particles greater than 0.8 microns. A Bluetooth and GPS option enables data to be streamed in real time onto an Android tablet.

In the examples shown, a DV3000 instrument was used to perform a survey of public roads around two chemical plants in Immingham in the UK in August 2016. The instrument was mounted in an automobile and driven around the plants where it was Bluetooth and GPS enabled, allowing for results to be viewed in real time on an Android tablet during the analysis of the areas. Additionally, this feature allows for data to be pinpointed to an exact location during the reprocessing of data at a later time. The highest benzene levels were close to 100 ug/m3 or approximately 30 ppb, while ethylbenzene levels peaked to 225 ug/m3, approximately 50 ppb.

Free to read

This article has been unlocked and is ready to read.

Download


Digital Edition

AET 28.4 Oct/Nov 2024

November 2024

Gas Detection - Go from lagging to leading: why investment in gas detection makes sense Air Monitoring - Swirl and vortex meters will aid green hydrogen production - Beyond the Stack: Emi...

View all digital editions

Events

Clean Fuels Conference

Jan 20 2025 San Diego, CA, USA

Carrefour des Gestions Locales de L'eau

Jan 22 2025 Rennes, France

Safety, Health & Wellbeing LIVE

Jan 22 2025 Manchester, UK

SLAS 2025

Jan 25 2025 San Diego, CA, USA

InterAqua 2025

Jan 29 2025 Tokyo, Japan

View all events