• Taking PFAS in water analysis to Infinity and beyond

    PFAS analysis

    Taking PFAS in water analysis to Infinity and beyond

    Understanding PFAS analytical methods and regulations and choosing the right instruments and consumables is key to getting your lab ready for PFAS analysis. To shorten start-up time, Agilent provides LC/MS/MS eMethods to get you up and running in the shortest time possible.

    The PFAS in Drinking and Surface Water by LC/TQ eMethod is verified for the separation and reliable detection of 100 native and isotopically labelled PFAS in drinking and wastewaters, including 60 PFAS with reported method detection limits. The method includes target compounds that are part of global standard methods and regulatory lists such as, ISO 21675:2019, Europe (EU) WfD & DWD, Japan Drinking Water Quality Standards, German DIN methods, US-EPA Method 537.1, EPA Method 533, SW-846 Method 8327, SW-846 Draft Method 8327, ASTM D7979-19 and ASTM 7968-17a. 

    The Agilent 1290 Infinity II LC and the Agilent 6470 triple quadrupole LC/MS are used in combination to provide high-quality LC/MS/MS results. Sample preparation is performed with Agilent SampliQ weak anion exchange (WAX) cartridges, and an Agilent ZORBAX RRHD Eclipse Plus C18 column is used in LC analysis.

    In addition to acquisition and quantitation methods, the PFAS eMethod includes sample preparation protocols, a detailed training video with a step-by-step workflow guide, and references to expertly selected consumables and supplies to minimize cost and effort to design and plan the required analyses.

    The eMethod makes use of the Agilent PFAS multiple reaction monitoring (MRM) database for triple quadrupole LC/MS, which features data for over 100 native and isotopically labelled PFAS. The database includes details of the intrinsic properties and identifiers of PFAS such as chemical name, CAS number, and molecular formula. It also features optimized MRM parameters for the analysis of 72 native and 36 isotopically labelled compound from 14 PFAS groups, as well as retention time data from optimized methods.

    The eMethod is designed for labs that want a widely applicable testing method and that do not plan to run dedicated regulated methods. For labs running regulated methods, the eMethod in conjunction with the Agilent PFAS MRM database can be a helpful building block to modify existing methods to expand analytical capabilities.


    Digital Edition

    IET 35.2 March

    April 2025

    Air Monitoring - Probe Sampling in Hazardous Areas Under Extreme Conditions - New, Game-Changing Sensor for Methane Emissions - Blue Sky Thinking: a 50-year Retrospective on Technological Prog...

    View all digital editions

    Events

    Canadian Hydrogen Convention

    Apr 29 2025 Edmonton, AB, Canada

    EnTech 2025

    Apr 30 2025 Ankara, Turkey

    Sensor + Test 2025

    May 06 2025 Nuremberg, Germany

    Oil & Gas Asia

    May 10 2025 Karachi, Pakistan

    SETAC Europe

    May 11 2025 Vienna, Austria

    View all events