The new Jerome J505 Mercury Vapour Analyser is a portable fluorescence spectroscopy analyser with a range of 0.05ug to 500ug Hg. The J505 incorporates a detection cell design which is simpler, smaller, lighter weight and more robust than competing spectroscopy instruments. 

The highly efficient optical cell requires less flow to purge the system, allowing the J505 to run at low flow rates, therefore significantly reducing the sample dilution requirements associated with rival instruments. A low flow rate is vital for making accurate readings at low and very low mercury concentrations.

The analyser is fully calibrated to internationally traceable standards ensuring accuracy across the entire concentration range of the sensor. An on-board data logging capability eliminates the need for manual recording of sample data, minimises the amount of time personnel need to spend in contaminated areas and provides excellent traceability of results, which are displayed alongside date, time, location and ambient temperature data. A programmable auto-sampling mode facilitates unattended monitoring over extended periods.

Features: 

  • Meets EPA & ATSDR Clean up Levels;
  • Programmable Auto Sampling Mode;
  • Choice of three Units of Measurement (nanograms, micrograms, milligrams); 
  • Colour Display with Easy to Use Menu System;
  • Battery Operation for 10+ Hours | Battery Charges in 3 Hours or Less; and
  • Integrated Data Logging Saves all Test Results (excludes search mode).

Specifications:

Resolution - 0.01 μg/m3 (10ng/m3) in standard test mode. 
Detection Range - 0.05 to 500 μg/m3
Data Storage - Up to 10,000 test results, 100 test locations. 
Operating Environment - 5 to 45°C, non-condensing, non-explosive. 
Accuracy -

  • 0.3 μg/m3 ±15% 
  • 1 μg/m3 ±10% 
  • 25 μg/m3 ±10% 
  • 100 μg/m3 ±10% 

Typical Response Time -

  • Search 8 sec. first reading; continuous 1 sec. updates 
  • Quick 16 sec. 
  • Standard 28 sec. 

Flow Rate - 1 litre/minute. 
Power Requirements - 12VDC power adapter runs on 100-240VAC, 0.8A. 
Internal Battery Pack - Rechargeable nickel metal hydride (NiMH) with 10+ hours of operation. Battery charges in three hours or less. 
Dimensions - 12” L x 6.2” W x 8.4” H 
Weight - 6.5lb 
Output - USB flash drive.

For more information regarding the J505, please visit the website or contact Dave Quelch for assistance.


Digital Edition

IET 35.2 March

April 2025

Air Monitoring - Probe Sampling in Hazardous Areas Under Extreme Conditions - New, Game-Changing Sensor for Methane Emissions - Blue Sky Thinking: a 50-year Retrospective on Technological Prog...

View all digital editions

Events

Canadian Hydrogen Convention

Apr 29 2025 Edmonton, AB, Canada

EnTech 2025

Apr 30 2025 Ankara, Turkey

Sensor + Test 2025

May 06 2025 Nuremberg, Germany

Oil & Gas Asia

May 10 2025 Karachi, Pakistan

SETAC Europe

May 11 2025 Vienna, Austria

View all events