CEMS
AQE 2018 workshop abstract
Sep 10 2018
Study of the effect of PM size distribution on CEMS response in a large-scale coal CHP plant
Erkki Lamminen, Samuli Pylkkönen, Mikko Moisio, Dekati Ltd.
Continuous emissions monitoring systems (CEMS) are used in power plants to monitor the level of emitted particulate matter from the stack. In order to evaluate which changes affect CEM calibration, it is important to understand the sources of possible changes in PM size distribution inside the stack.
In this study we 1) compared the second by second response of a PM CEM to a non-continuous real-time PM instrument and 2) evaluated the effect of changes in PM size distribution on the CEM response in a large-scale coal CHP plant. To examine the PM size distribution changes, we used the Dekati® High Temperature ELPI®+. The advantages of the High Temperature ELPI®+ include its capability of measuring PM size distribution in real-time, and directly from the high temperature source. The results show very similar trend for mass concentration for CEM and HT-ELPI®+, but also that the number size distribution shape is significantly different before and after a large baghouse cleaning spike.
Dekati Ltd instruments are distributed by Scielutions Ltd (UK). Scielutions Ltd. provides aerosol instruments and measurement services from leading manufacturers
Digital Edition
AET 28.4 Oct/Nov 2024
November 2024
Gas Detection - Go from lagging to leading: why investment in gas detection makes sense Air Monitoring - Swirl and vortex meters will aid green hydrogen production - Beyond the Stack: Emi...
View all digital editions
Events
Jan 14 2025 Abu Dhabi, UAE
Jan 20 2025 San Diego, CA, USA
Carrefour des Gestions Locales de L'eau
Jan 22 2025 Rennes, France
Safety, Health & Wellbeing LIVE
Jan 22 2025 Manchester, UK
Jan 25 2025 San Diego, CA, USA