Fast, Accurate and Automatic Nitrogen Determination in Soils and Plants
Aug 11 2010
Nitrogen content analysis is essential when determining the quality of various types of crops for feeding and processing, as well as for N-cycle and N-fixation monitoring in agricultural and environmental research. The Thermo Scientific FLASH 4000 Nitrogen/Protein analyzer offers a rapid, safe and accurate alternative to the classic Kjeldahl method.
A new application note demonstrating rapid, automatic and reproducible quantitative determination of nitrogen in soils and plants is now available. The note, entitled “Nitrogen Determination in Soils and Plants by the Thermo Scientific FLASH 4000 Elemental Analyzer,” is free to download
Nitrogen content in soils is an important evaluation parameter of organic matter. The analyses of nitrogen content provide valuable information regarding the deficiency or excess of nutritional elements important to plant growth. For maximum analytical performance, nitrogen content determination in soils and plants must be performed using accurate instrumental analytical techniques while also avoiding the use of toxic chemicals. To achieve this, the classic Kjeldahl method has been replaced by the Dumas combustion method, a simple and automatic technique that does not require sample digestion of toxic chemicals and facilitates faster analysis combined with excellent reproducibility. The FLASH 4000 is based on the Dumas combustion method, providing significant advantages over the Kjeldahl method including laboratory staff safety, improved sample throughput, automation, reduced operational costs and quantitative determination of nitrogen in a large range of concentrations.
The new application note details the analytical configuration and analytical conditions required to achieve rapid, safe and reliable nitrogen content determination in soil and plant samples. The correct quantity of oxygen, correlated to the weight and type of sample, is determined automatically by the OxyTune™ feature of Thermo Scientific Eager Xperience software which facilitates the complete combustion of the sample.
Experimental results demonstrate excellent reproducibility and no memory effect when changing the type of sample, indicating the complete detection of the nitrogen present in the sample. The FLASH 4000 is able to analyze nitrogen in a wide range of samples from low to high content without matrix effects. In addition, the nitrogen data obtained using the analyzer is within the tolerable levels set by WEPAL International Round Robin Tests, demonstrating the high-performance of the instrument.
For more information about the Thermo Scientific FLASH 4000 nitrogen/protein analyzer visit www.thermoscientific.com/flash4000
Digital Edition
AET 28.4 Oct/Nov 2024
November 2024
Gas Detection - Go from lagging to leading: why investment in gas detection makes sense Air Monitoring - Swirl and vortex meters will aid green hydrogen production - Beyond the Stack: Emi...
View all digital editions
Events
Nov 27 2024 Istanbul, Turkey
H2O Accadueo International Water Exhibition
Nov 27 2024 Bari, Italy
Biogas Convention & Trade Fair 2024
Nov 27 2024 Hanover, Germany
Dec 02 2024 London, UK
Dec 03 2024 Dusseldorf, Germany