Environmental Laboratory

Scandinavian success: Leading the way in airport PFAS remediation

Aug 08 2024

Author: Jeffrey Lewis on behalf of ECT2: a Montrose Environmental Group company

Free to read

Articles are free to download. Unlock the article to be shown more content, graphs and images.

Introduction

Airports worldwide are tackling the critical environmental issue of PFAS (per- and polyfluoroalkyl substances) contamination, primarily caused by the prolonged use of firefighting foams. Jeffrey Lewis from ECT2 discusses the extensive contamination of water sources and the health and environmental risks involved. With new regulatory pressures, airports are adopting rigorous testing and remediation methods. A leading example from Scandinavia shows a major airport initiating a comprehensive remediation project for PFAS from fire training activities, establishing new environmental standards in the aviation industry.

 

Addressing PFAS contamination in the aviation sector

Airports globally are grappling with a pressing environmental challenge: PFAS contamination. Historically, many airports used firefighting foams containing PFAS during emergency drills and operational responses. This persistent use has led to widespread contamination of nearby groundwater and surface water, posing significant environmental and health risks.
The use of aqueous film forming foam (AFFF), containing PFAS, in emergency response and firefighting training has raised significant health and environmental concerns. This foam, previously used at airports, military bases, and fire training sites, has contaminated various environments. With new European and global regulations emerging, the airport community is under increasing pressure to investigate, test, and remediate PFAS contamination. These evolving regulations are set to shape the treatment and management of PFAS, potentially introducing future liabilities. As a result, treating PFAS contamination is becoming a critical focus for airports to ensure both regulatory compliance and environmental safety.
In Scandinavia, the issue has prompted decisive action. One major airport, recognising the critical nature of this contamination, has taken a proactive stance on environmental stewardship by initiating a comprehensive remediation project.
In 2008, the airport undertook an environmental study, testing for PFAS in surface water bodies across its premises. It was during this study that the team discovered perfluorooctane sulfonate (PFOS) for the first time. Over the next decade, following continuous investigations, it became clear that the main source of PFAS contamination at the airport originated from its fire training facility, more specifically from the type of fire-fighting foam typically used in the past.
This led to decisive action in 2022, when the airport committed to remediate this primary source of PFAS. Launched in September 2023, this ambitious PFAS remediation project is setting new benchmarks in environmental water remediation. The decision to address PFAS-contaminated groundwater reflects a growing awareness and responsibility among airport authorities to remedy the impacts of past practices.

 

Evaluating technologies: From foam fractionation to ion exchange

The airport operator was determined to address the PFAS contamination with a robust and efficient approach that not only met its stringent criteria for effectiveness and sustainability but also offered economic feasibility and rapid deployment. The search for the right solution led to a competitive tendering process, during which the airport operator’s environmental team evaluated a range of progressive treatment technologies.
Among the contenders were foam fractionation, granular activated carbon (GAC), and ion exchange, each offering unique benefits and potential drawbacks. After thorough analysis and comparison, the airport operator chose ECT2’s ion exchange technology, specifically its SORBIX™ PURE resin, for its high efficiency and effectiveness in removing contaminants.
The chosen system was designed to tackle challenging site-specific needs. It was engineered to handle a maximum flow rate of 17 cubic metres per hour, dealing with influent PFAS concentrations as high as 6,200 nanograms per litre.
This included tackling several hundred nanograms per litre of notoriously difficult-to-remove short-chain compounds such as PFBA (perfluorobutanoic acid) and PFPeA (perfluoropentanoic acid).
The selection of SORBIX™ PURE demonstrated the airport’s commitment to significantly reducing PFAS levels, aligning with both environmental and health safety standards. This initiative not only aimed to rectify the impacts of past practices but also set a new benchmark for environmental responsibility in the aviation sector.

 

Efficiency in PFAS treatment

The remediation process began with an initial GAC pre-treatment stage, which was engineered to eliminate as many non-PFAS contaminants as possible. Following this, the water was channelled into vessels packed with SORBIX™ PURE ion exchange resin – special plastic beads that have been soaked in salt water, so that chloride ions attach themselves to the positively charged nitrogen ions in the resin. When the PFAS-contaminated water is added, the PFAS ions displace these chloride ions so that the PFAS is attached to the resin instead of remaining in the surrounding water. This process is what is meant by the term ‘ion exchange’.
The contractual obligation was to remove 93% of the mass balance of PFAS. As of June 2024, the combined actions of ion exchange and adsorption have removed 98%, exceeding client expectations. This process is also removing 100% of the European Food Safety Authority’s ‘PFAS 4’ (perfluorooctanoic acid (PFOA), perfluorooctane sulfonate (PFOS), perfluorononanoic acid (PFNA) and perfluorohexane sulfonic acid (PFHxS)) from the water onsite.
ECT2’s ion exchange resin is particularly adept at tackling hard-to-remove short-chain PFAS molecules, with a removal capacity that is 13 times more effective than traditional methods such as GAC. This efficiency translates into considerable savings for highly contaminated sites, as ion exchange systems are smaller, require less upkeep, produce minimal waste, and use less material to achieve superior results. Furthermore,
SORBIX™ resins can be regenerated and the effluent concentrated using patented processes that enhance cost-effectiveness, reduce environmental liabilities, and improve overall treatment outcomes.
The bespoke solution from ECT2 was delivered and operational within just seven months, a testament to the efficiency and dedication of the team. As of June 2024, the system has
treated over 65 million litres of water, demonstrating its effectiveness and setting a precedent for future environmental aviation remediation projects and across a range of other industry sectors.

 

Commitment to remediation: A model for airports

This initiative is part of a broader movement within the aviation industry to reconcile operational safety with environmental conservation. As airports continue to navigate the complexities

of PFAS contamination, the balance between maintaining rigorous safety protocols and protecting natural resources remains an important concern. The airport’s commitment to remediation not only mitigates the immediate environmental impact but also sets a precedent for other airports facing
similar challenges.

 

About Jeffrey Lewis

Jeffrey Lewis brings over 20 years of industry experience to the ECT2 team where he currently leads as Sweden General Manager. Prior to joining ECT2, Jeff has worked in various research and consulting roles for companies such as Tyréns and the Swedish Defence Research Agency, FOI. He is an expert in hydrogeological assessment, remediation strategies and specialises in groundwater contaminant transport. Jeff is past president of the Swedish branch of the International Association of Hydrogeologists and has served on the editorial board of Hydrogeology Journal. He is a member of the Swedish Geotechnical Society, and Naturvetarna, Swedish Association of Professional Scientists, is a Docent (Associate Professor) at the University of Gothenburg, and has authored over 20 consulting reports for the industry. Jeff holds a Bachelor’s and Master’s Degree in Chemical Engineering from Royal Military College of Canada and earned his PhD in Earth Science from the University of Quebec.

 

About ECT2

ECT2 (www.ect2.com), a Montrose Environmental Group company, is a global leader in technology solutions for removing challenging contaminants from water and vapor. The company specialises in PFAS and offers a comprehensive suite of services for understanding and managing its impacts. At the forefront of their solutions is a proprietary and cost-effective approach that utilises synthetic resins for efficient contaminant removal and that “regenerates” this resin to enable multiple reuse cycles, minimising waste. With a track record of successful applications around the world, ECT2’s systems have achieved industry-leading uptime and deliver contaminant removal well below specified limits. With over 350 systems deployed worldwide, the company has treated more than 30 billion litres of water to date.

 

Free to read

Articles are free to download. Please login to read this article or create an account.


Digital Edition

AET 28.2 April/May 2024

May 2024

Business News - Teledyne Marine expands with the acquisition of Valeport - Signal partners with gas analysis experts in Korea Air Monitoring - Continuous Fine Particulate Emission Monitor...

View all digital editions

Events

World Water Week

Aug 25 2024 Stockholm, Sweden and online

KEET 2024

Aug 28 2024 Gwangju, South Korea

Aquatech Mexico

Sep 03 2024 Mexico City, Mexico

Water Expo China

Sep 04 2024 Nanjing, China

JASIS 2024

Sep 04 2024 Chiba, Tokyo, Japan

View all events